1. Motor imbalance Field balance motor

2. Motor bearings not properly seated Inspect and replace as required

3. Motor drive coupling out of balance Field balance coupling

4. Misalignment of pump, casting, discharge

head, column, or bowls

Check for overall pump concentricity, remove and straighten bent

shaft, consider replacing bent shaft

5. Discharge head misaligned by improper

mounting or pipe strain

Reduce pipe strain, ensure pipe strain does not exceed limits

recommended by Peerless Pump

6. Bent shafting Remove and straighten bent shaft, consider replacing bent shaft

7. Worn pump bearings Pull pump and inspect for bent shaft, straighten bent shaft,

replace wear ring, remove any abrasive material, adjust Impeller

setting per Peerless recommendations

8. Clogged impeller or foreign material in pump Disassemble pump, inspect and remove foreign material,

reassemble and set impeller with correct lateral settings

9. Improper impeller balance Remove Impellers and balance per Peerless Pump

recommendations

10. Vortex problems in sump Adding of baffels or flow direction devices can reduce this.

11. Resonance – system frequency at or near pump

speed

Stiffening or softening the system can be accomplished by many

different methods.